AC Voltage/Current Instrumentation - Back to Product Guide
Made in Santa Ana, CA
Electromagnetic Compatibility
Year 2000 Compliant
3 1/2 DIGIT AC POWER LINE MONITOR
201AN-AC5
50.0 to 199.9 Vac Range (100 mV Resolution)
50 to 650 Vac range (1 V Resolution)
Bright, 0.56" (14.2 mm) LED Display
Automatic Zero
Display Hold and Test
Screw-terminal Barrier Strip
Short 4.1" (104 mm) Deep 1/8 DIN Case

OPTIONS
Isolated 9-32 Vdc Power
Isolated 26-56 Vdc Power
3 1/2 Digit AC Power Line Monitor
Price List
Mechanical Reference
1/8 DIN (2A) Case
Mechanical Reference
Connections Diagram

Model 201AN-AC is a low-cost, compact 3 1/2 digit panel meter for AC power line monitoring. It uses a half-wave rectifier calibrated to read the RMS value of sinusoidal signals. Two input ranges are jumper- selectable: 50.0 to 199.9 Vac with 100 mV resolution and accuracy optimized for 115 Vac, and 50 to 650 V with 1 V resolution and accuracy optimized for 230 Vac. The meter fits a standard 1/8 DIN panel cutout 3.62" x 1.77" (92 x 45 mm) and requires a depth of less than 4.1" (104 mm) behind the panel. A screw-terminal barrier strip for signal and power is standard.

SPECIFICATIONS
Noise Rejection (AC GND to SIG GND)
CMR: 120 dB, DC to 60 Hz
CMV: 1500 Vp per HV test, 354 Vp per IEC spacing

Accuracy at 25░C (10% to 100% of full-scale range)

Maximum error (reading - actual): 50.0 to 199.9 V range: ▒0.006 (R-115 V) ▒0.1 V and 50 to 650 V range: ▒0.006 (R-230 V) ▒1 V
Span tempco: ▒0.01% of reading/░C
Step response: 1 s
Warmup to rated accuracy: 10 min

ANALOG-TO-DIGITAL CONVERSION
Technique:
Dual-slope, average-value
Read rate: 2.5/s
Integration period: 100 ms

DISPLAY
Type: 7-segment, red LED Height: 0.56" (14.2 mm)
Symbols: 1.8.8.8
Decimal points: Three positions programmable internally or at connector, 10 mA average sink
Overrange indication: Three least-significant digits blank

DIGITAL CONTROLS
HOLD and TEST inputs: TTL or 5 V CMOS compatible

POWER
AC voltages: 115 or 230 Vac ▒15%
AC frequency: 49-440 Hz
DC voltages: 9-32 Vdc, isolated to 300 Vp; 26-56 Vdc, isolated to 300 Vp
Power consumption: 2.4 W (nominal)
Output voltages: +4.7 Vdc and -4.6 Vdc ▒5%, 10 mA max

ENVIRONMENTAL
Operating temperature:
0 to 60░C
Storage temperature: -40 to +85░C
Relative humidity: 95% at 40░C (non-condensing)

MECHANICAL
Dimensions:
NEWPORT« DIN2A (short 1/8 DIN) case (See mechanical section for drawings)
Weight: 14 oz (400 g)
Case material: 94V-0 UL-rated polycarbonate

Signal Input
Range
199.9 Vac
650 Vac
Resolution
100 Mv
1 V
Overvoltage protection
650 Vac
650 Vac
Input resistance
1 M ohm
1 M ohm
Bias current
1 pA
1 pA
Configuration: Half-wave average, RMS-calibrated
Zero: Automatic
Frequency: 49-440 Hz

To Order ( * Complete Model No.) Prices Shown in U.S. Dollars
Model Description Price
201AN-
( * )
( * )
Standard case
$180
301AN-
( * )
( * )
INFINITYÖ style case
$210
INPUT MEASUREMENT RANGE
 
AC5
  50.0 to 199.9 Vac  
 
AC6
  60 to 650 Vac  
POWER
   
-
115 Vac, 50/60/400 Hz
N/C
   
C1
230 Vac, 50/60/400 Hz
N/C
   
C3C
9-32 Vdc, isolated to 300 Vp
$120
   
C3E
26-56 Vdc, isolated to 300 Vp
$120
Ordering Example: 201AN-AC5 3 1/2 digit panel meter with standard case and 50 to 199.9 Vac measurement range, $180.



Fast Quotes on Products
HOME / PRODUCT GUIDE / TECHNICAL REFERENCE
NEWPORT Electronics, Inc. (714) 540-4914 or Contact Us